Yaskawa SGDB Manual do Utilizador Página 150

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 149
APPLICATIONS OF Σ-SERIES PRODUCTS
3.7.6 Using OL Warning and Alarm Output Signals
138
3.7.6 Using OL Warning and Alarm Output Signals
This section describes how to wire and use photocoupler output signals OLWRN (over-
load warning) and OL (overload alarm).
These two output signals are output when operation under the rated current or more con-
tinues for a certain period of time. The overload warning signal is output in 20% of the
time required to output the overload alarm signal.
Operating time
(seconds)
Instantaneous peak current
Rated current
Overload Alarm level
Overload warning level
Current
SGDB SERVOPACK
I/O power supply
Photocoupler Output
Per output:
Maximum operation
voltage: 30 VDC
Maximum output
current: 50 mADC
OLWRN+
(OL+)
OLWRN
(OL)
Output /OLWRN
Overload Warning Output For Speed/Torque
Control and
Position Control
Output OL
Overload Alarm Output For Speed/Torque
Control and
Position Control
OLWRN is an overload warning output signal, and OL is an overload alarm output signal.
ON
status:
Circuit is closed or signal is at low level. Normal state
OFF
status:
Circuit is open or signal is at high level. Warning or alarm state
Use the following parameter to specify the pin to which the signal is to be output.
Cn-2D
OUTSEL Output
signal
selection
Setting Range:
110 to 666
Factory
Setting:
210
For
Speed/Torque
Control and
Position Control
This parameter is used to specify a function signal as the 1CN output signal.