1
.
VS-606PC
3
INVERTER
MAIN
UNIT
(Cont'd)
1
.6 .6
Check
Points
at
Test
Run
The
following
describes
the
check
points
at
test
run
.
If
any
fault
occurs,
recheck
the
wiring
and
load
status
.
For
details,
refer
to
Par
.
1
.8
.3
"Corrective
Action
for
Motor
Faults"
on page 52
.
Motor
rotates
smoothly
.
Motor
rotates
in
the
proper
direction
.
Motor
does
not
have
any
abnormal
vibration
or
beat
.
Acceleration
or
deceleration
goes
smoothly
.
Current
suitable
for
load
flows
.
Status
display
LEDs
or
digital
operator
display
is
proper
.
PRECAUTIONS
(1)
The
motor
does
not
start
up
if
both
FWD
and
REV
run
signals
are
turned
ON
simultaneous]
:
y
.
If
they
are
turned
ON
simultaneously during
run,
the
motor
stops
according
to
the
stopping
method
selection
of
constant
(No
.01)
3rd
digit
.
(Deceleration
to
a
stop
is
selected
for
factory
setting
.)
(2)
If
a
fault
occurs
during
acceleration or deceleration
and
the
motor
coasts
to
a
stop,
check
the
motor
stop
and
then
the
following
items
.
For
details,
refer
to
Par
.
1
.8
"FAULT
DISPLAY
AND
TROUBLESHOOTING"
on page
46
.
Load
is
not
excessively
large
.
Accel/decel
time
is
long
enough
for
load
.
(3)
Resetting
must
be
performed
by
fault reset
input
signal
(or
RESET
key
of
the
digital
operator)
or
by
turning
OFF
the
power
supply
.
(4)
If
an
input
contactor
is
used
to
start
and
stop
the
inverter,
the
maximum
number
of
starts/hour
is
1
.
Vista de página 53