1
.
VS-606PC3
INVERTER
MAIN
UNIT
(Cont"d)
1
.8 .2
Alarm
Display
and
Contents
Alarms,
among
inverter
protective
functions,
do
not
operate
fault
contact
output
and
returns
to
the
former
operation
status
automatically
when
the
factor
is
removed
.
The
following
shows
the
types
and
contents
.
Table
1
.10
Alarm
Display
and
Contents
Alarm
Display
Digital
Inverter
LED
Display*
Contents
Possible
Cause/
Operator
Corrective
Actions
DS
1
(GR,`
DS2
;RD
;
EF
(Simulta-
Both
FWD
and
REV
neous
Input
commands
are
"closed"
of
FWD
and
"
for
500
ms
or
larger
.
Check
the
control
interface
REV
Commands
Inverter
stops
accord-
circuit
.
mg
to
constant
No
.
01
.
blinks
.
External
baseblock
is
BB
input
.
(External
Inverter
output
shuts
Baseblock')
off
.
;Operation
restarts
when
blinks
.
® ~
the
external
baseblock
Check
the
control
interface
signal
is
removed
.
circuit
.
For
the
external
base-
block
signal,
refer
to
"MULTIFUNCTION
CONTACT
INPUT
FUNCTION
SELECTION"
on
page
115