FSP Amplifier Short Form Installation Guide Wiring
5.5.2. Single-phase 200V 0.8kW and 1.5kW Main Circuit
Observe the following points.
1. Connect main power supply shown below to L1 and L3 terminals.
Power supply is single-phase, 220 to 230VAC +10% to -15%,
50/60Hz. If power supply of 187 V (-15% of 220V) or less is used,
alarm A.41 indicating voltage shortage, may occur when accelerating
to max speed with max torque of motor.
2. Short-circuit B2 and B3 terminals using the internal regenerative
resistor. If capacity of the regenerative resistor is insufficient, remove
the lead between B2 and B3 terminals and connect an external
regenerative resistor unit to B1 and B2 terminals.
34
Personal Computer
Cable type P/N: YS-12
Host controller
FSP Amplifier is compatible with most
PLC motion controllers and indexers.
Used for a servomotor
with
a brake.