FSP Amplifier Short Form Installation Guide Installation Conditions of EMC Directive
8. Installation Conditions of EMC Directive
The following conditions must be satisfied for a combination of servomotor and the
FSP Amplifier to comply with EMC Directives (EN61000-6-2 and EN55011,
Group 1 Class A).
8.1. EMC Installation Conditions
This section describes the test installation conditions prepared by YEA that meet
EM C guidelines for all FSP Amplifier models. The actual EM C level may differ
depending on the actual system’s configuration, wiring and other conditions.
8.1.1. Installation: Single & Three-phase 100/200V FSP Amplifier
(PC)
FSP-A3A* to -30A*(30W to 3.0kW)
Represents option with PC connected to CN3 connector.
Note: Shielded Box with door closed
Cable
length
approx . 5m
44
NOISE
FILTER
NOISE
FILTE R
Brake Power
Supply
CLAMP
CLAMP
AC Power Supply
Single-phase
200V
or
Three-phase
200V
50/ 60Hz
U, V,
W
L1 , L2
L1C , L2C
CLAMP
CLAMP
CORE
CORE
CORE CORE
CORE
BRAKE
MOTO
R
ENCODER
PE
CORE
CO RE
Personal
Computer
PE
CN3
CN1
CN2
Ground Plate/ Shielded Box
Cable len
g
th
approx . 3m
Mains Cable
Length
Approx . 2m
F
S
P Am
p
2
4
3
1
Symbol Cable Name Specification
PC communication cable Shielded cable
Servomotor cable Shielded cable
Encoder cable Shielded cable
AC line cable Shielded cable