FSP Amplifier Short Form Installation Guide Appendix A
52
11. Appendix A
11.1. I/O Signals Connector CN1
CN1 connector is required to connect the host controller to the FSP Amplifier. It
comprised of a connector and a connector cover.
Mating 50-Pin Connector Model (Kit)
YEA P/N Conne ctor Parts
Connector
10150-3000VE *
Case
4J4003
10350-52A0-008 *
* Manufactured by Sumitomo 3M Co.
Terminal Layout
Pin No. Name Pin No. Name
1 Signal Ground 26 /V-CMP- (out 1-)
2 Signal Ground 27 /TGON+ (out 2+)
3 PL1 28 /TGON- (out 2-)
4 SEN 29 /S-RDY+ (out 3+)
5 V-REF 30 /S-RDY- (out 3-)
6 Signal Ground 31 ALM+ (out 4+)
7 PULS 32 ALM- (out 4-)
8 /PULS 33 PAO
9 T-REF 34 /PAO
10 Signal Ground 35 PBO
11 SIGN 36 /PBO
12 /SIGN 37 ALO1
13 PL2 38 ALO2
14 /CLR 39 ALO3
15 CLR 40 /S-ON
16 TMON 41 /P-CON
17 VTG 42 P-OT
18 PL3 43 N-OT
19 PCO 44 /ALM-RST
20 /PCO 45 /P-CL
21 BAT+ 46 /N-CL
22 BAT- 47 +24V IN
23 NC* 48 PSO
24 NC* 49 /PSO
25 /V-CMP+ (out 1+) 50 NC*
Note: NC – Leave contact open (Not Connected)