9.3. Cable Specifications
Shield cables should be used for the following cables:
AC power input line cable (between p ower sup p ly and noise filter)
Servomotor cable (between FSP Amplifier and servomotor)
Encoder cable (between FSP Amplifier and servomotor)
Controller cable (between FSP Amp lifier and controller)
9.4. Recommended Ferrite Cores
Cable Encoder Cable Power Cable
Manuf acturer Absolute Serial 30W to 400W 0.8kW to 5kW
Tokin Corp. ESD-SR-25 ESD-SR-25 ESD-SR-25
Fair-Rite Corp. 0444173551 0444164181 0444173551
TDK Corp. PC40T96x20x70
9.5. Shield Box
A shield box, a closed metallic enclosure, should be used for shielding from
electromagnetic interference. The structure of the box should allow the main
body, door, cooling unit etc. to be attached to the ground. The box opening
should be as small as possible.