Yaskawa Sigma-5 User Manual: MECHATROLINK-II Commands Manual do Utilizador Página 111

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 142
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 110
5 Command Related Parameters
5.2.7 STATUS Field and Monitor Related Settings
5-22
NEAR Signal Width Setting
Set the NEAR signal status detection range.
Note: NEAR = 1 when the feedback position (APOS) is within the NEAR signal detection range.
Zero-speed (ZSPD) Detection Level Setting
Set the ZSPD signal status detection level during speed control (VELCTRL command).
Speed Coincidence (VCMP) Detection Level Setting
Set the VCMP signal status detection level during speed control (VELCTRL command).
Parameter
No.
Name
Data
Size
(byte)
Setting Range Unit
Factory
Setting
Pn524 NEAR Signal Width 4 0 to 1073741824 Reference unit 7
Feedback position
(APOS)
NEAR Signal Width
(Pn524)
NEAR detection
range
Target position
(TPOS)
Parameter
No.
Name
Data
Size
(byte)
Setting Range Unit
Factory
Setting
Pn502
Rotation Detection Level
(For rotational servomotors)
2 1 to 10000
min
-1
20
Pn581
Travel Detection Level
(For linear servomotors)
2 1 to 5000 mm/s 20
Parameter
No.
Name
Data
Size
(byte)
Setting Range Unit
Factory
Setting
Pn503
Speed Coincidence Signal Output Width
(For rotational servomotors)
2 0 to 100
min
-1
10
Pn582
Speed Coincidence Signal Output Width
(For linear servomotors)
2 0 to 100 mm/s 10
Vista de página 110
1 2 ... 106 107 108 109 110 111 112 113 114 115 116 ... 141 142

Comentários a estes Manuais

Sem comentários