1.2 N.C. Contact instruction (NCC)
1-3
1.2 N.C. Contact instruction (NCC)
[Outline]
The NCC sets the value of the bit output to OFF when the value of the referenced register is 1 (ON),
and to ON when the value of the referenced register is 0 (OFF).
[Format]
Symbol : NCC
Full Name : NC Contact
Category : RELAY
Icon :
[Parameter]
Parameter Name Setting
Relay No. · Any bit type register
· Any bit type register with subscript
[Program Example]
When MB000100 becomes ON, MB000101 becomes OFF.
MB000100
ON
OFF
MB000101
ON
OFF