TECHNICAL NOTE
RDA INITIALIZATION #2 function
Function block for MP2000 series
<RDAINIT2> Function Block Summary
The Reserved Data Area (RDA) Initialization function block (RDAINIT2) block is used to initialize the
values in the RDA for a specific axis. Without the proper values in the RDA the some motion blocks may
not work properly. The RDAINIT1 block must also be used to complete the initialization of all mandatory
RDA values.
Function Block Diagram
<RDAINIT2> Function Block Operation Notes
To use the function block, it must be placed in an ‘A’ drawing.
Both RDA init 1 and 2 blocks should be used together for each axis. RDAINIT2
block sets the hardware module number, the axis number within the module,
rated speed, and post-quad axis encoder resolution.
This function uses no drawing registers to run.
File: MP2000_IndividualFunctionDocument_RevC 132/168
Doc Number: eng.MCD.05.101 11/17/2005